This quick reference guide helps you understand the 2D SWE for small parts using the ACUSON Sequoia ultrasound system with the VA30 software.

Quick Reference Card Virtual Touch 2D SWE ACUSON Sequoia Ultrasound System VA30 SW release BRE siemens-healthineers.com/ultrasound Using 2D shear wave elastography (SWE) to measure shear velocity (Vs) in meters per second (m/s) and elasticity (E) in kilopascal (kPa) for applications in Small Parts Step 1 OL4 Step 3 Breast SWE • Select compatible transducer and • SWE tab is default application on exam preset1 touch screen Step 2 Step 4 Update • Press VT (Virtual Touch) located on VT • If required, roll the trackball control panel to reposition the region of interest (ROI) • If required, press the right or left Set key and roll the trackball to resize ROI (if necessary) • Use minimal scanning pressure to prevent pre-compression effect • Press Update on the control panel to begin acquisition 1 2D SWE imaging is compatible with 5C1, DAX: General, Abdomen; 10L4: General, Thyroid, Breast, MSK; 18L6: General, Thyroid, Breast. SIEMENS Healthineers Step 5 • When the acquisition is complete, the system automatically freezes, emits one audible “beep” and activates the Velocity or Elasticity display mode • Adjust Min and/or Max Velocity or Elasticity Increase range if measured value exceeds Min Velocity Max Velocity Min Elasticity Max Elasticity - 0.5 4 50 range by displaying “High” Decrease range if better visualization of - velocity of stiffness differences is needed • To check the quality of your image prior to measurement, ensure that the Quality and Quality Velocity Displacement map options are selected and m/s displayed on the touch screen above the Dual display. If the maps are not displayed, Live Dual select either of the keys to open the pop-up menu of map choices • Measurements should be taken in regions with high quality (green to yellow-green) Velocity Elasticity Quality Displacement Displacement 2D Only m/s kPa in the Quality display Quality Velocity • Correlate the areas in the Velocity or Elasticity image with shear wave signal-to- noise ratio and Displacement amplitude Note: During freeze, a cooling timer indicates remaining seconds until transducer is available for image acquisition. During a short cooling time (e.g., 1–2 seconds), the timer appears and then disappears very quickly. Step 6 • If required, the units (m/s and kPa) may be altered by selecting the desired unit from Velocity Elasticity the touch screen display options m/s kPa • To display the SWE image in full screen format (if desired), select the Live Dual key Live Dual to exit the split screen format • If required, rotate the VT rotary dial on the control panel to change the transparency of the 2D SWE image VT 2 siemens-healthineers.com/ultrasound Measurements Shear Velocity and Elasticity -- + Measurements can be performed or viewed in the Shear Velocity Velocity, Elasticity, Quality or Displacement display modes. 18L6 Breast • Press Caliper on the control panel – Shear Velocity TIB:0.39 TIC:0.63 is the default measurement tool TIS:0.39 MI:1.17 65fps 95% • Roll trackball to position measurement ROI. ROIs 2D Mid should be placed at the same depth in the image 0dB/DR65 c= 1446 for comparison measurements of normal/abnormal SWE Velocity Transp: 60% tissue. In Live Dual, the measurement ROI can be placed on either image. • If needed, rotate the ROI Diameter to resize • Shear wave measurements and measurement ROI 1 Vs Median=2.36 m/s depth and diameter are displayed near image (Fig. 1) E Median=16.7 kPa Depth=0.86 cm Diam=0.30 cm 2 Vs Median=1.12 m/s • To display a measurement in the report, select the E Median=3.8 kPa Depth=0.87 cm desired measurement label Diam=0.30 cm Fig. 1: Velocity display mode in Live Dual format and shear wave • If desired, press Set key and roll trackball to perform additional measurements or select Delete on the measurements of a breast lesion. control panel to delete the measurement • Select Report on the left side of touch screen to view, store, print or transfer shear wave measurements Note: If the measurement ROI value exceeds the current maximum velocity or elasticity setting, the measured results display HIGH for the shear wave value. If the measurement ROI value is lower than the current minimum velocity and elasticity setting, the measured results display LOW. The measured results display X.XX (for velocity) or XX.X (for elasticity) if the shear wave was not detected within the ROI or if a measurement is performed outside the ROI. Shadow Calipers Shadow Shadow calipers are used to duplicate and display a measurement on the adjacent image to compare the 1 D=0.30 cm size and/or location of a lesion. Velocity 10L4 Breast In Live Dual, press Caliper on the control panel TIB:0.67 • TIC:1.14 TIS-0.67 MI:1.16 • Select the measurement tool 54fps 95% 2D H High • Shadow is activated as a default on the touch screen 0dB/DR65 c=1446 SWE • Measure the right or left image Transp: 60% • The Shadow measurement is displayed in the measured results Tip: Shadow may be used with the Shear Velocity tool when Live Dual is activated. 4cm 1 D=1.64 cm siemens-healthineers.com/ultrasound 3 For the proper use of the software or hardware, please always use At Siemens Healthineers, our purpose is to enable healthcare the Operator Manual or Instructions for Use (hereinafter collectively providers to increase value by empowering them on their journey “Operator Manual”) issued by Siemens Healthineers. This material is towards expanding precision medicine, transforming care delivery, to be used as training material only and shall by no means substitute and improving patient experience, all enabled by digitalizing the Operator Manual. Any material used in this training will not be healthcare. updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the An estimated five million patients worldwide everyday benefit from training. The Operator Manual shall be used as your main reference, our innovative technologies and services in the areas of diagnostic in particular for relevant safety information like warnings and and therapeutic imaging, laboratory diagnostics and molecular cautions. medicine as well as digital health and enterprise services. Note: Some functions shown in this material are optional and might We’re a leading medical technology company with over 120 years not be part of your system. of experience and 18,500 patents globally. With over 50,000 employees in more than 70 countries, we’ll continue to innovate Certain products, product related claims or functionalities described and shape the future of healthcare. in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Sequoia and Virtual Touch are trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003240578 · 11484 1221 online · ©Siemens Medical Solutions USA, Inc., 2021

  • 2D
  • swe
  • 2D
  • swe
  • liver
  • abdomen
  • elastography
  • ACUSON Sequoia
  • Sequoia
  • elasto
  • VA30