Virtual Touch Reference Values - Society of Radiologists in Ultrasound Values
Please note that the learning material is for training purposes only!
For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions.
Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases.
Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information.
ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc. Copyright © Siemens Healthcare GmbH, 2022
“Some of the indications on the use of CEUS may be off-label in some countries. Users shall always refer to the national SPC’s (Summary of Product Characteristics) or PI (product Information for the USA) which are the official product labelling approved by the Regulatory Authorities”
For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
Virtual Touch Reference Values Absent or mild fibrosis Significant fibrosis Severe fibrosis Cirrhosis Metavir Score F0–F1 F2 F3 F4 10543 0421 · ©Siemens Medical Solutions USA, Inc., 2021 Siemens Healthineers 1.2 m/s 1.3 m/s 1.5 m/s 1.7 m/s values† 4 kPa 5 kPa 7 kPa 9 kPa 1.3 m/s 1.7 m/s 2.1 m/s Society of Radiologists in Ultrasound (SRU)†† Not applicable < 9 kPa rules out cACLD in the < 5 kPa Likely Normal absence of other clinical signs > 13 kPa rules in cACLD 9–13 kPa suggestive of cACLD needs further testing 10 sample median; IQR/Median < 15% m/s, < 30% kPa. cACLD = compensated Advanced Chronic Liver Disease. This guide is based on meta-analysis and clinical studies using Siemens Healthineers Ultrasound. This guide is not intended to be used as a conversion table for liver stiffness readings to fibrosis stage or replace the performing physician’s judgment for the final diagnosis. † Mild: F ≥ 1: 1.18-1.19 m/s, F ≥ 2: 1.21-1.34 m/s, F ≥ 3: 1.54-1.61 m/s, F = 4: 1.80-2 m/s NAFLD: F ≥ 1: 1.10 m/s, F ≥ 2: 1.16 m/s, F ≥ 3: 1.48 m/s, F = 4: 1.63 m/s Sporea I., et al. Romanian National Guidelines and Practical Recommendations on Liver Elastography. Med Ultrasound. 2014, Vol 16, no2, 123-138. DOI:10.11152/mu.2013.2066.162.is1sb2 Significant/Severe/Cirrhosis: F ≥ 2: 1.34 m/s, F ≥ 3: 1.55 m/s, F = 4: 1.80 m/s Friedrich-Rust, M., et al. Performance of acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis. Journal of Viral Hepatitis, 2012 doi:10.1111/j.1365-2893.2011.01537.x F ≥ 2: 1.30 m/s, F = 4: 1.80 m/s Bota S., et al. Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis. Liver International. 2013: 33: 1138-1147. DOI:10.1111/liv.12240 †† Society of Radiologists in Ultrasound (SRU): Barr R., et al. Update to the Society of Radiologists in Ultrasound Elastography Consensus Statement. Radiology. 2020; 296:263-274. https://doi.org/10.11.48/radiol.2020192437 SIEMENS Healthineers Rev: April 2021