Welcome to the Cleaning the Ch Reagent Gripper puncture device on the Itelica CI Analyzer video. When troubleshooting errors, it may be necessary to check and clean the Ch Reagent Gripper puncture device this. Video demonstrates how to clean the device in the area for system. Status Select the Itelica CI Analyzer. Ensure the analyzer is in the stop state to stop the analyzer. Select the stop icon. Select Stop immediately to cancel all samples in process or select Stop to Stop after completing all samples in process. To unlock the front left cover. Select. The lock icon and wait for the icon to indicate the unlocked state to. Unlock the front right cover, select the lock icon and wait for the icon to indicate the unlocked state. Proceed. With the following steps to clean the reagent gripper puncture device. To open the front left cover, place one hand on the bottom left corner of the cover and then pull open the cover. To open the front right cover, place one hand on the bottom right corner of the cover and then pull open the cover. Locate the reagent compartment loading arm. Ensure that the Gripper Puncher device is clean. To clean the device, use lintfree tissues or gauze saturated with special reagent water to close and lock the front right cover. Using the door handle, pull the cover down until it stops, then place a hand in the middle of the cover and push it closed to close and lock the front left cover. Using the door handle, pull the cover down until it stops. Then place a hand in the middle of the cover and push it closed. Select the. Play button to resume the system. This completes the procedure for cleaning the reagent gripper puncture device on the Itelica CI Analyzer.
16 76 30682 130682 Cleaning the CH Reagent Gripper Puncture Device on the Atellica® CI Analyzer Video SIEMENS Atellica Solution LabManager System DL Ready Connected to PCC AF030672 Front Covers Back Covers Patient Sample Processing Left Cover Unlocked Right Cover Locked Left Cover Closed Right Cover Closed Request Access 10:31 AM Intervention Needed 9:31 AM Maintenance QC Statistics Calibration Due Assay Status QC Scheduler AF030680 9:27 AM 8:46 AM Inprocess: CH-02 QC Needs 8:37 AM 3 Warnings 8:06 AM Load STAT Rack Clear All Racks ? Q losed ess To cancel all samples in process, select Stop Immedlately. To stop after completing all samples in process, select Stop. To cancel the requested activity, select Cancel. Stop Immediately Stop Cancel 8 Activities Due 1 Patlent (non-STAT) Stopped 0 Errors Gulded Workflows < 1 2 3 DL-CI Do not clean the reagent compartment while the probes and gripper are accessing reagent packs. Moving probes and gripper can cause bodily harm. Left Cover Locked 1 Patient (non-STAT) 3N Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2023
- VIDEO RELEASE TWO