
syngo.via MR VB60 Delta Job Aid
This delta job aid provides information about new features and functionalities in MR with syngo.via VB60.
SIEMENS Healthineers syngo.via MR VB60 Delta Job Aid Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 04/21/2021 | HOOD05162003184313 Unrestricted © Siemens Healthineers, 2021 syngo.via MR VB60 Delta Job Aid SIEMENS Healthineers Table of Contents B-Value Calculation 3 MR Neurology C + Current Current.MR.MPRAGE GRAPPA2.latest. Volume_C MR Neurology Reading MR Neurology Morphometry Deviation Map 4 MRC31/7E94187E1985E6/8593FB/ Pingle Learn Perfusion Mismatch Segments Maps Eval. MPRAGE GRAPPA2 Prostate AI 5 Mean Brain Neurology Curve Mornho Settings x Findings AFL 10cm PIDE Tools L TR 2300.0 SP L43.4 TE 3.0 FoV 270*344 Synch MPR THICK : ... NORM/DIS3D Align Hide Reset Graphics Timepoi. V Redo Enable Follow-Up Mode Deviation Map Colors Edit Snapshot Print Export Undo Blend Factor for Deviation Map Image 50 Image Blend Factor for Label Map Min Percentil 1:01 PM Percentile for Volumes* 2 Effective Date: 04/21/2021 | HOOD05162003184313 Unrestricted © Siemens Healthineers, 2021 MR Analysis Tools, High B-Value Calculation SIEMENS Healthineers In the Computed b-value images area, you can move the AHR ADC & b-value ? X b-value slider or enter the b-value in the text field. St. Georg Klinikum ep2d_diffusion_tra_SMS2_TRACEW ADC Map Calculation Config. In VB60, the range for b-value adjustment is between 0 Input Series ep2d_diffusion_tra_SMS2_TRACEW B-Value_01_0 and 10,000. By default, the value is 1,400. B-Value 02_1000 RFP To enhance the pixel intensity value of high value results, 5cm the Scaling factor can be adjusted between 1 and 1,000. F TR 3100.0 SP H27.7 TE 108.0 FoV 230*230 DIFF/TRACEW/NORM/DIS2D Zoom 1.55 Threshold 10+ Remove AHR Result Series Name ADC_b0_1000_ep2d_diffusion_tra_SMS2_TRACEW St. Georg Klinikum Computed b-value images CALC_b9353_b0_1000_ep2d_diffusion_tra_SMS2_TRACEW Enable Computed b-value b-value 9353 Auto Preview Scaling 100 RFP Result Series Name CALC_b9353_b0_1000_ep2d_diffusion_tra_SMS2_1 5cm Target Segment F b-value ADC TR 3100.0 SP H27.7 TE 108.0 FoV 230*230 CALC_BVALUE/NORM/DIS2D Zoom 1.55 OK Preview Cance 3 Effective Date: 04/21/2021 | HOOD05162003184313 Unrestricted © Siemens Healthineers, 2021 MR Neurology Brain Morphometry Deviation Map SIEMENS Healthineers The deviation map is displayed in the image MR Neurology Q. + Current Current.MR.MPRAGE GRAPPA2.latest. Volume_C MR Neurology Settings X segment and shows the different brain regions, MR Neurology Reading Perfusion Map Set Available Colors Morphometry Settings color-coded to indicate the degree of deviation MRC31/7E94187E1985E6/8593FB/ Learn Perfusion Mismatch Segments Maps Eval. MPRAGE GRAPPA2 Default Settings Blend Facto Percentile for Volumes* 90 from the average normative volume. The color Mean Marnhn Blend Fa range is based on the standard deviation. The x Preprocessing Se Automatic gene Automatic Findings color is configurable. Selection Language fo AFL Enable Fo Disable p Standard Colors data Send gen No deviations or minor deviations are shown in Deviation Map Co Advanced Max Deviation green, large deviations in red. You can also Percentile+ configure the color and thresholds of these Tools L L TR 2300.0 SP L43.4 Min Deviation TE 3.0 FoV 270*344 Align MPR THICK : ... NORM/DIS3D Full Text Hide Hide Lines Reset colors. Synch Graphics Timepoi ... Enable Follow-Up Mode Deviation Map Colors Edit 4 Snapshot Print Export mage Undo Redo Blend Factor for Deviation Map 50 Image Blend Factor for Label Map 50 Min Percentil Restore 1: 01 PM Percentile for Volumes* 90 The deviation map colors can be changed permanently by the user in MR Neurology Settings. In the MR Neurology Brain Morphometry step, the colors can be changed temporarily. 4 Effective Date: 04/21/2021 | HOOD05162003184313 Unrestricted © Siemens Healthineers, 2021 MR Prostate Lesion Detection and Classification SIEMENS Healthineers The location is automatically recognized for manually drawn findings if it is located within the gland volume and is drawn with the standard tools (ROI, VOI, distance line, and marker) on the transversal T2 series. Region, laterality, and location are prefilled in the findings details. For all the findings the ADC value, 10th percentile, and median are displayed. A Details MR Prostate 2 Current 12/14/2018 Volume 31.74 cm3 Preview for Lesion 1 Type MR Prostate Min / Max: 45.00 /798.00 Mean/SD: 271.30 /80.13 Volume 2.47 cm3 Attributes that are filled in automatically are indicated by . Check that Seminal Vesicles the attributes are correct. R AFS APS L Region TZa TZa T2a Region TZa PZa PZa TZp TZp Laterality Right Laterality right Location Apical Location Apical Base T2W T2W AFS, A R Gland Volume TZA TZa DWI DWI PZa PZa Volume 40.24 cm3 TZp TZp Min / Max: 45.00 /798.00 DCE PZpl PZpm PZpm LAY Mean/SD: 280.87 /81.40 DCE EPE Mid Volume 2.47 cm3 EPE PI-RADS ¿? 5 MPS , AFS 1 of 1 Results. Score Index Lesion No PZs Lesion Level of Suspicion 96 1 22pm | P2pen , Lesion 1 Score 5 Median ADC 791; 10% 618 Overall Rating Index Lesion Comment Marker Tools O ROI Circle ROI Urethra Freehand 5 Effective Date: 04/21/2021 | HOOD05162003184313 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 6 Effective Date: 04/21/2021 | HOOD05162003184313 Unrestricted © Siemens Healthineers, 2021
- syngo.via
- MR
- delta job aid
- JA