
SCORM TRAVERSE
SCORM TRAVERSE
Continue Button Unrestricted © Siemens Healthineers, 2021 Job Aid Effective Date: 11-Aug-2021| HOOD05162003214634 Template Effective Date: 27 May 2019 | HOOD05162003010284 The animation of the dot pulse can be optionally switched off on the master layout. Go to View > Slide Master After that go to Animations > Animations Pane. Select additional title motifs from the layout palette. Go to Home > Slides > Layout Unrestricted © Siemens Healthineers, 2021 Job Aid Effective Date: 11-Aug-2021| HOOD05162003214634 Continue Shutdown Atellica® HEMA 570 580 SMS Weekly Shutdown and Weekly Startup Introduction audf-hema-weekly-shutdown-startup-introduction.mp3 Once per week, you will need to perform a weekly shutdown followed by a weekly startup on the Atellica HEMA (HEE-mah) slidemaker stainer. This video will show you how to perform both procedures. Atellica® HEMA 570 580 SMS Weekly Shutdown Methanol shutdown you will need audf-hema-weekly-shutdown-you-will-need.mp3 To perform a weekly shutdown, you will need methanol and four empty reagent bottles. Methanol is highly flammable and dangerous. The use of methanol can cause very serious irreversible effects through inhalation, if in contact with skin, or if swallowed. So, before you begin this procedure, ensure you are using personal protective equipment and have proper ventilation. Atellica® HEMA 570 580 SMS Weekly Shutdown Select Shutdown shutdown select shutdown audf-hema-weekly-shutdown-select-shutdown.mp3 First, from the analyzer home screen, select shutdown. Select Shutdown to continue. Atellica® HEMA 570 580 SMS Weekly Shutdown Select Weekly Shutdown shutdown select weekly shutdown audf-hema-weekly-shutdown-select-weekly-shutdown.mp3 Next, in the S M S section, select weekly shutdown. Select Weekly Shutdown to continue. Atellica® HEMA 570 580 SMS Weekly Shutdown Shutdown directions prompt 1 audf-hema-weekly-shutdown-directions1.mp3 A window will appear with instructions. This video will demonstrate these instructions for you, step-by-step. Atellica® HEMA 570 580 SMS Weekly Shutdown shutdown staining straws to one bottle audf-hema-weekly-shutdown-staining-straws-to-one-bottle.mp3 Remove both staining straws from their stain bottles and place them in one of the empty bottles. Close the stain bottles with their caps. Atellica® HEMA 570 580 SMS Weekly Shutdown shutdown buffer straw to empty bottle audf-hema-weekly-shutdown-buffer-straw-to-empty-bottle.mp3 Remove the buffer straw from its bottle and place it in a different empty bottle. Close the buffer bottle with its cap. Atellica® HEMA 570 580 SMS Weekly Shutdown Methanol 300mL 300mL shutdown methanol to bottles audf-hema-weekly-shutdown-methanol-to-bottles.mp3 Next, transfer approximately 300 milliliters of methanol to each of the two remaining bottles. Atellica® HEMA 570 580 SMS Weekly Shutdown 300mL 300mL shutdown status before next audf-hema-weekly-shutdown-status-before-next-button.mp3 You should now have the following setup: One bottle with both staining straws One bottle with the buffer straw Two bottles, each with 300 milliliters of methanol Atellica® HEMA 570 580 SMS Weekly Shutdown Select Next Shutdown steps1-3 complete audf-hema-weekly-shutdown-1-3-complete.mp3 We have completed steps one through three. Select next to continue. Select Next to continue. Atellica® HEMA 570 580 SMS Weekly Shutdown Shutdown directions prompt 2 audf-hema-weekly-shutdown-directions2.mp3 More steps are added to the existing instructions. This video will demonstrate those steps. Atellica® HEMA 570 580 SMS Weekly Shutdown 300mL 300mL Shutdown straws to methanol bottles audf-hema-weekly-shutdown-straws-to-methanol-bottles.mp3 Now, transfer the two staining straws to one of the methanol bottles and the buffer straw to the other methanol bottle. Atellica® HEMA 570 580 SMS Weekly Shutdown Select Next Shutdown directions prompt 2 audf-hema-weekly-shutdown-directions-complete.mp3 We have completed the directions. Select the Next button to continue. Select Next to continue. Atellica® HEMA 570 580 SMS Weekly Shutdown 300mL 300mL shutdown complete audf-hema-weekly-shutdown-complete.mp3 The slidemaker stainer will draw methanol through the straws and into the staining wells. Leave the straws as they are until the next weekly startup. The weekly shutdown process is now complete. Next, we will demonstrate how to perform a weekly startup Startup Atellica® HEMA 570 580 SMS Weekly Startup Startup introduction audf-hema-weekly-startup-introduction.mp3 The next part of this video will show you how to perform a weekly startup on the Atellica HEMA Slidemaker Stainer. Whenever a weekly shutdown has been performed, a weekly startup procedure must be carried out the next time the SlideMaker Stainer is started. When you begin this procedure, there should be one bottle containing two staining straws and one bottle containing the buffer straw. There may be some residual methanol left in the bottles with the straws. So, before you begin this procedure, ensure you are using personal protective equipment and have proper ventilation. You will also need the buffer bottle, two clean, empty reagent bottles, and the two stain bottles. Atellica® HEMA 570 580 SMS Weekly Startup Select Startup Startup select home startup audf-hema-weekly-startup-select-home-startup.mp3 To begin, select startup on the analyzer home screen. Select Startup to continue. Atellica® HEMA 570 580 SMS Weekly Startup Select Startup Startup select sms startup audf-hema-weekly-startup-select-sms-startup.mp3 In the S M S section, select Startup. Select Startup to continue. Atellica® HEMA 570 580 SMS Weekly Startup Startup directions prompt 1 audf-hema-weekly-startup-directions1.mp3 A window will appear with instructions. This video will demonstrate these instructions for you, step-by-step. Atellica® HEMA 570 580 SMS Weekly Startup Startup straws to empty bottles audf-hema-weekly-startup-straws-to-empty-bottles.mp3 Both staining straws should be in one bottle from the weekly shutdown procedure. Remove them and place them into one empty bottle together. The buffer straw should be in a bottle from the weekly shutdown procedure. Remove it and place it into another empty bottle. Atellica® HEMA 570 580 SMS Weekly Startup Startup close reagent bottles audf-hema-weekly-startup-close-reagent-bottles.mp3 Close the reagent bottles that formerly contained methanol with their caps. Atellica® HEMA 570 580 SMS Weekly Startup Select Next Startup 1-4 complete audf-hema-weekly-startup-1-4-complete.mp3 We have completed steps one through four. Select the next button to continue. Select Next to continue. Atellica® HEMA 570 580 SMS Weekly Startup Startup on air audf-hema-weekly-startup-cycle-on-air.mp3 The analyzer will now perform a startup cycle on air to prevent contamination of staining reagents. Atellica® HEMA 570 580 SMS Weekly Startup Startup continue prompt audf-hema-weekly-startup-directions2.mp3 More steps are added to the existing instructions. This video will demonstrate those steps. Atellica® HEMA 570 580 SMS Weekly Startup Startup straws to stain bottles audf-hema-weekly-startup-stain-straws-to-stain-bottles.mp3 Transfer the staining straws into their stain bottles. Ensure the correct straw goes into the correct stain bottle. Atellica® HEMA 570 580 SMS Weekly Startup Startup buffer straw to buffer bottle audf-hema-weekly-startup-buffer-straws-to-buffer-bottle.mp3 Transfer the buffer straw to the buffer bottle. Atellica® HEMA 570 580 SMS Weekly Startup Select Next Startup directions complete audf-hema-weekly-startup-directions-complete.mp3 We have completed the remaining steps on the screen. Select the next button to continue. Select Next to continue. Atellica® HEMA 570 580 SMS Weekly Startup Startup priming audf-hema-weekly-startup-priming.mp3 The analyzer will now run a priming cycle of the stains and buffer. Atellica® HEMA 570 580 SMS Weekly Startup Startup complete audf-hema-weekly-startup-complete.mp3 When the priming cycle is finished, the weekly startup procedure is complete. The analyzer and slidemaker stainer are now ready to analyze samples. Conclusion Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer HOOD05162003236180 | Effective Date 22-Nov-2021 1 Shutdown 1.1 Introduction 1.2 shutdown you will need 1.3 shutdown select shutdown 1.4 shutdown select weekly shutdown 1.6 shutdown staining straws to one bottle 1.7 shutdown buffer straw to empty bottle 1.9 shutdown status before next 1.8 shutdown methanol to bottles 1.5 Shutdown directions prompt 1 1.10 Shutdown steps1-3 complete 1.12 Shutdown straws to methanol bottles 1.11 Shutdown directions prompt 2 1.13 Shutdown directions prompt 2 1.14 shutdown complete 2 Startup 2.1 Startup introduction 2.2 Startup select home startup 2.3 Startup select sms startup 2.5 Startup straws to empty bottles 2.6 Startup close reagent bottles 2.4 Startup directions prompt 1 2.7 Startup 1-4 complete 2.8 Startup on air 2.9 Startup continue prompt 2.12 Startup directions complete 2.13 Startup priming 2.14 Startup complete 2.10 Startup straws to stain bottles 2.11 Startup buffer straw to buffer bottle 3 Conclusion 3.1 Disclaimer
- SCORM TRAVERSE