POCcelerator™ Client Print and Archive QC Results Job Aid

POCcelerator™ Client Print and Archive QC Results Job Aid

This job aid provides instructions to print and archive QC results from the POCcelerator™ Client QC Monitor.

POCcelerator™ Client – SIEMENS Healthineers Print and Archive QC Results Job Aid Print QC Results Poc POCcelerator™ - PCC_Demo_English X File View Quality controls Setup Extra Info Result M Manual qc input Monitor Browse /archive Ctrl+1 Period Print Statistical values 1. Select QC Monitor from: No. of controls 6/8 QC violations Target value 75.00 mg/dL until: Check all incomplete QC data Ctrl+Alt+Q 2. Select QC chart screen Mean value 76.00 mg/dl Parameter- Control 3. Enter the desired selection criteria for period of Sample: Vollblut Level Level 1 Standard deviation 4.73 mg/dl Analytes: Glu Lot no. 153871 Variation coefficient 6.23 % time, device, parameter and control i + 1:1 Quality control measurements 4. Select Quality controls > Print > Print selection in 105- the menu bar Range by law 100 Range by manufacturer Target value 5. Select the print symbol QC result 90 Refresh 85 80 75 mg/dl 70 65- ----- 60- 55 50- 451 7.09.2015 09.09.2015 11.09.2015 3.09.2015 15.09.2015 QC chart Incomplete QC data QC violations 6 0 Conworx Conworx (1000)=] 1 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Browse / archive X Print and Archive QC Results Job Aid Check QC results using the following filters: Timeframe from: 01/04/2015 until: Ward Model Device Siemens Healthineers -Stat JAIl Archive QC All available sample types, analytes, levels and lots will be checked according to the criteria above. Do the following Archiving measurement series guarantees reliable documentation C Browse Archive and audit of all quality controls. Additionally, archiving improves 5 ......................... software performance. Archived data cannot be changed anymore. After archiving it will not be possible to insert any additional data measured in the archived period. Please make sure that 1. Select QC Monitor any data from that period contained in the Incomplete QC Data table is completed prior to archiving. 2. Select QC chart screen 3. Select the desired selection criteria Set archive date 4. Select Quality controls > Browse/archive in the menu bar 6 31/03/2022 23:59:59 5. Select the Archive radio button Ok 7 Cancel 6. Set an archive date and time 7. Select Ok 9 Archiving of QC series POCcelerator Client starts the archive process Ward Model Device Sample ty Analyte Level Lot Comment • Lhiversitätsward 8000A Z2 (11112) Van Level 1 179-1-920 Universitätswerd 8000A 22 [11112) 6 Vollblut Vollblut Citrate AlLevel 1 12348 8. In the Archiving of QC series window, highlight a measurement Universitätsward 800DA 22 (11112) Vollblut Glu Level 1 12347 Universitätswerd 8000A 22 (11112) Vollblut Lovel t 12347 Universitatsward 8000A 22 [11112) Vollblut Level 1 12347 When outliers get series and enter a conclusion comment for a marked Lang Lhiversitätsward 8000A 22 (11112) 7 Vollblut Lang Level 1 Calc archived, they will no Universitätsward 8000A Z2 (11112) Vollblut Van Level 1 12347 longer be displayed in the tramc light measurement series OR mark multiple measurement series to Universitätsward 8000A 22 [11112) Vollblut Van Level 1 Calc Archived 8 measurements can add a conclusion comment no longer be updated 9. Select Archive all to confirm your input Archive all 9 Cancel • The measurement series will be archived Comment for archiving QC data Select. 4 out of 8. Note: Each QC series needs a conclusion comment before archiving, unless in Extra > Program Options > QC the Allow archiving of 2 measurement series without conclusion comment checkbox is selected. Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. POCcelerator and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 3 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022

  • poccelerator
  • client
  • qc monitor
  • print
  • archive
  • qc