POCcelerator™ Client Manage Device Information Job Aid
This job aid provides an overview of managing device information and instructions to assign a device flag to a model from the POCcelerator™ Client Setup.
POCcelerator™ Client – SIEMENS Healthineers Manage Device Information Job Aid Selection Poc Model FreeStyle Precision Pro 0 × Model Definition ModelName Navi 2 PCC ABL 7xx Model definition| Rule-based auto-validation | Configuration | Monitoring frequencies New data record ABL 90 Flex Edit data record 4 When a device is connected to POCcelerator software for the ABL715 Model name FreeStyle Precision Pro Accuchek in form Copy data record first time, the model is automatically created in the setup Accuchek in form II 5 Manufacturer Abbott Delete data record data. Avoximeter 1000E Bayer Lab0405 Family Accept 7 Bayer Lab1245 • Model name and download configuration are adopted Bayer Lab1260 6 Model type Strip meter Unit Use Cancel from the Meditrac interface Bayer Lab1265 B-Hemoglobin-Photometer Filter • Model definition, rule-based auto-validation, C-Lab E-learning cours. User group assignment configuration and monitoring frequencies can be COMED DPS Assign external course E-learning courses customized manually 3 FreeStyle Precision Pro GEM 3000 No. of data records 23 GEM 4000 Show i-Stat active Model definition: KX21 inactive POCcelerator 1. Select Setup > Devices > Models pocH-100i StatStrip • Model X window appears Activate [ Activation time ] Deactivate 2. Select Model definition tab Now Now Select the desired model 08/09/2015 11:06:24 3. 4. Select Edit data record 5. Select manufacturer and family from the dropdown lists Note: Do not create models manually if they are connectable. They 6. Select model type, if required Strip meter should be selected if the target value of a will automatically be created in setup data after first connection. • control depends on the regent lot 1 7. Select Accept Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Manage Device Information Job Aid Rule-Based Auto-Validation Model _PCC_ × Navigate Edit Model definition Rule-based auto-validation Configuration | Monitoring frequencies New data record Allows users to define the rules for which technical errors Edit data record patient measurements, QC measurements or linearity Test for following contents: Data record Mark Discard Copy data record measurements are to be checked. No case number UL Delete data record • Mark – data records that do not meet the test Case number begins with: criterion are set to Error status Accept Length of the case number 7 Discard – data records that do not meet the test Min.: 0 Max.: 20 Cancel • criterion are not added to the database and are Syntax of case number Filter immediately deleted and cannot be restored .. Mask editor Case number not known M No order number Patient measurement results that break these rules are: Result with out of reference range flag (H, L) No. of data records 63 • Marked (Error status) in the Result Monitor and not Result with out of critical range flag (HH, LL) Show forwarded to the LIS, OR discarded Result with out of measurement range flag (>, <) active Result with specified device flag ( inactive Assign QC measurement results that break these rules are: • Marked (Error status) and entered into the Incomplete QC data table in the QC Monitor, OR discarded Patients Consumables QC Device user |Devices Linearity 2 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Manage Device Information Job Aid Model _PCC_ O × Navigate Edit 2 Model definition Rule-based auto-validation| Configuration | Monitoring frequencies New data record Edit data record 4 Test for following contents: Data record Mark Discard Copy data record Assign a Device Flag to a Model No case number Delete data record Case number begins with: Accept 9 Length of the case number 1. Select the desired model Min.: 0 Max.: 20 Cancel 2. Select the Rule-based auto-validation tab Syntax of case number Filter 3. Select the Patients tab .. Mask editor 4. Select Edit data record Case number not known No order number 5. Define the rules for which technical errors from Result with out of reference range flag (H, L) No. of data records 63 patient measurements are to be checked by 5 Result with out of critical range flag (HH, LL) Show selecting the Mark and/or Discard checkboxes Result with out of measurement range flag (>, <) active Result with specified device flag O inactive 6. To specify which device flags to check, select ..... ASSign ..... Assign 6 7. Assign the desired device flags to the model using the arrow buttons 8. Select Accept Patients Consumables QC Device user Devices | Linearity 9. Select Accept 3 Assign device flags to a model × Device flag assignment for model "_PCC_": 7 Not assigned: Assigned: A A .............................................................. AA B V D MS < N QC < < 3 8 Effective Date: 20 Apr 2022| HOOD05162003271046 Accept Cancel Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Manage Device Information Job Aid Configuration Model ABL 7xx O X Navigate Edit Model definition| Rule-based auto-validation Configuration Monitoring frequencies New data record If a device is set into operation for the first time, all data Edit data record that can be downloaded from POCcelerator software to Enable download of the following data: Device users Copy data record the model are automatically activated here. IT system user Patients Delete data record QC lots Options can be activated and deactivated at any time. QC sub lots Accept User comments Reagent lots Cancel Wards Modifications of settings in the Configuration tab are Device configuration Filter made at the model template level: • Settings can be overwritten per device in Setup > Devices > Devices No. of data records 63 Show active Note: All configuration changes take immediate inactive effect for all devices of the model type (even if users did not select Edit data record, Accept or Cancel). Downloads Overwrite device settings 4 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Client – SIEMENS Healthineers Manage Device Information Job Aid Monitoring Frequencies Model ABL 7xx O X Navigate Edit Model definition | Rule-based auto-validation | Configuration Monitoring frequencies New data record Allows users to define the time (frequency) at least one Edit data record valid QC measurement must be received. Threshold values Copy data record Delete data record Different periods of time for the monitoring of POCT QC frequency Download frequency Reporting frequency devices can be defined. Days Hours Days Hours Days Hours Accept 17 0 10 Cancel Devices that exceed these defined frequencies cause an Filter error message in the Process Monitor and set the associated signal light to red. No. of data records 63 Monitoring frequencies can be defined at the model Show template level: active inactive • Settings can be overwritten per device in Setup > Devices > Devices Overwrite device settings 5 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. POCcelerator and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 6 Effective Date: 20 Apr 2022| HOOD05162003271046 Unrestricted © Siemens Healthineers, 2022
- poccelerator
- client
- setup
- model definition
- rule based autovalidation
- device flags
- configuration
- monitoring frequencies