NAEOTOM Alpha VA50 Update Training - Spectral Imaging Video
Coming up in this video, we cover the new Spectral Imaging features in VA50.
Welcome to the Neatham Alpha Software V A50 update training for the new features of spectral imaging. Coming up in this training, we will cover the new spectral imaging features in V A50. The uhr, or High res ultra quantum plus scan modes have been available on the Neoton alpha since the beginning. Now new with the V A50 software version, the scan mode High Res ultra Quantum Plus allows you to obtain spectral reconstructions from a Uhr acquisition. Previously this was not possible and all reconstructions had to be at 3D Recon. This new feature is particularly interesting for the combination and fusion of high res lung images with perfusion maps or of high res bone images with bone marrow edema maps. High Res ultra quantum plus scans utilize the 120 by 0.2 millimeters collimation and the higher KV settings of 120 or 140. To better understand this feature, let's first discuss what a high resolution reconstruction is. A high res reconstruction is any reconstruction with a 0.2 millimeter slice thickness. Or any kernel sharpness above 76 and up to a 98. All high res reconstructions needing those parameters will continue to be at 3D Recon. Spectral reconstructions are not possible with high res parameters. Now that we know what a high res reconstruction is, let's discuss spectral reconstructions. Spectral reconstructions, inline results, multi energy ranges and SPP datasets are now available in a high res ultra quantum plus scan mode. They can be used for further dual energy workflows. The requirement for all spectral recons is a standard resolution reconstruction that contains. Slice thicknesses of oh .4 millimeters or larger. And the kernel sharpness of 76 and below. If these two Recon parameters are met, then spectral reconstructions are now possible. With VA52, additional dual energy application classes are available. Liver VBNC without fat maps and kidney stones are now ready for use in the application class for multi energy ranges. These two new dual energy workflows can also be utilized in the single via VB70 software.
120 80 0.85 0.50 6.0 0.20 0.40 70 SIEMENS . Healthineers NAEOTOM Alpha VA50 Update Training Spectral Imaging HOOD05162003279728 Unrestricted @ Siemens Healthineers, 2022 Introduction to the Video NAEOTOM Alpha VA50 Update Training Coming up in this Training: · New Spectral Imaging features Quantumplus Ultra-High-Resolution (UHR) Quantumplus UHR: With the VA50 software version, the scan mode Highresultra Quantumplus now allows you to obtain spectral reconstructions from a UHR acquisition. Previously this was not possible, and all reconstructions had to be a T3D recon. This new feature is particularly interesting for the combination / fusion of, for example, high-res lung images with perfusion maps or of high-res bone images with bone marrow edema maps. · Highresultra Quantumplus scans utilize the 120x0.2 mm collimation and the higher kV settings of 120 or 140. General Scan Scan Favorites Dose Timing Config Physio Scan Contrast Scan/Recon Scan Mode Acquisition [mm] CARE Dose4D kV Decision Trees CARE keV & CARE keV CARE keV IQ level optimized for Pitch Rot. Time Absolute Start [s] Delay [s] Thorax RoutineSpiralAdultThoraxHighresultraQuantumplus Full Non-Contrast 2.9s A High-res reconstruction is any recontware n, the scan with:n spectral reconstructions from a UHR a Recon Favori ... General Recon Recon&GO Image Impre ... Slice Increment Thickn ... Spectral Recon Window@120kV Kernel Or any Kernel sharpness above 76 and up to 98. Thorax 0.20 Br98 Q3 Mediastinum Br98 continue to be a T3D recon. · Spectral reconstructions are not possible with these High-res [mm] parameters. Thorax 0.20 Br40 Q3 Monoenergetic Pl ... Br40 Quantumplus UHR with: · 0.2mm slice thickness T3D All High-res reconstructions will Spectral reconstructions, Inline results, Multi Energy ranges and SPP datasets, are now available in a Highresultra Quantumplus scan mode. These you can use for further Dual Energy workflows. Monoenergetic Plus The requirement for all spectral recons is a standard None resolution reconstruction that contain: VNC lodine Slice thicknesses of 0.4 mm or larger Pure Calcium · And kernel sharpness of 76 and below. Pure Lumen If these 2 recon parameters are met, then spectral reconstructions are now possible. Dual Energy (DE) Applications Additional DE application classes: The following DE application classes are now available for photon-counting data Virtual Unenhanced (incl. Virtual Non-Contrast and lodine Maps) New in VA50: Liver VNC (without Fat Maps) New in VA50: Kidney Stones Recon Favori ... | General Recon Recon Box Physio Recon Inline Options Inline Results Organ Viewing High Application Class Energy Lung Lobe Direction Resolution in keV Data Set Segmentation Thorax 3.00 Qr40 Q3 ax DE Parallel Ranges No Organ Feet to He ... Off Liver VNC Virtual Unenhanced Kidney Stones Hint: These new DE workflows are also available on syngo.via, but only with VB70 software. Recon Box| Physio Recon | Auto Tasking Auto Tasking Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality"') may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2022 SIEMENS Health
- ct
- va50
- update
- spectral
- quantumplus
- uhr
- highres
- high-res
- de
- dual
- energy
- naeotom
- neotom
- alpha
- aphla