Multitom Rax Performing Real 3D Job Aid
This job aid is intended as performance support for Performing Real 3D exams on the FLC.
Performing Real 3D Job Aid Multitom Rax This document is intended as a job aid for performing 3D examinations on the Multitom RAX and will focus on the software-based workflow on the Fluorospot Compact (FLC) only. 1. Open the patient in the Examination tab on the FLC. 3D Examination, Knee 040822 150334 uGy*m2 Patient O 0 0.00 3D T Knee Examination Fluoro Rad 3D Examination, Knee 040822_150334 Postprocessing CP_antiiso Series 3D p/s 15 f/s 30 KV 0 KV 73 mA 0.0 mAs 0.5 Documentation ms 0.0 ms 6.3 0:00 Dose min mm Cu 0.2 mm Cu 0.3 30 p/s Focus mGy/min %<2 Gy 0.0 mGy 0.0 1 Press SmartMove button until patient transfer position is reached Door open OMa 0%HU Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 10 Aug 2021 | HILS 2224 Job Aid Effective Date: 02 Sep 2022 | HOOD05162003299670 Healthineers Job Aid | Performing Real 3D Effective Date: 02 Sep 2022 | HOOD05162003299670 2. Select the desired 3D OGP view for the exam. If necessary, make the suggested table adjustment. Select the image laterality. Verify that the correct grid is inserted. Patient Position and View Position Please define the patient position View Position Please define the image laterality Left Right Not Defined OK Cance Please define the image laterality Err 5548 / 240: Insert grid Left Right Not Defined with 115 cm H OK Cancel OK Please note: a) For standing 3D exams, place the RAXstand into the pre-defined position before moving the system into place (remove the tabletop from the table if necessary). b) For table-side upper extremities, move the system into place before attaching the arm board to the table. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 7 Job Aid | Performing Real 3D Effective Date: 02 Sep 2022 | HOOD05162003299670 3. If a transfer position is configured, press and hold the SmartMove button on the wireless remote control to move the system to the patient transfer position. i Press SmartMove button until patient transfer position is reached 8 # P 4. Keep the SmartMove button on the wireless remote control pressed to move to the start position of the 3D run. i Keep SmartMove button pressed to move to the start position of the 3D scan 8 700 5. Check that the region of interest of the patient lies in the light field and make sure that no collisions of the system with the patient occur. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 7 Job Aid | Performing Real 3D Effective Date: 02 Sep 2022 | HOOD05162003299670 6. Press and hold the SmartMove button on the wireless remote control to move to the second centering position. The system performs the 3D test run and moves the tube stand and detector stand along the programmed trajectory. i Press SmartMove button on the remote control to start the 3D test run 8 P 7. Make any necessary anatomy adjustments to set the center of the anatomy in the second position. Check whether the region of interest is positioned correctly in the light field. This will ensure that the object is in the isocenter. 8. Continue by pressing and holding the SmartMove button on the wireless remote control. The system will move back to the start position of the 3D run. i Press SmartMove button on the remote control to start the 3D test run 8 # P SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 7 Job Aid | Performing Real 3D Effective Date: 02 Sep 2022 | HOOD05162003299670 If the prerequisites for the 3D scan are fulfilled, the following message is displayed: i Position reached. Disengage button at remote control 9. Press the acquisition pushbutton fully down and hold it pressed until all the acquisitions are finished. Please note: If you prematurely release the acquisition, you will abort the spin. i Press Acquisition switch to start the 3D run SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 7 Job Aid | Performing Real 3D Effective Date: 02 Sep 2022 | HOOD05162003299670 10. After the 3D run is finished, please disengage the X-ray switch. i 3D run finished - Disengage X-ray switch You now have the possibility to repeat the examination again. If you press the SmartMove button, the system will move back to the patient • transfer position. If you press the lower left purple button, the system will move back to the start • position. i 3D finished. Move to Pat. Transfer Pos. by SmartMove button, or back to Start by lower left purple button 11. All the images are transferred to the syngo.via View&Go automatically. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 6 of 7 Job Aid | Performing Real 3D Effective Date: 02 Sep 2022 | HOOD05162003299670 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (here- inafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 7 of 7
- Multitom Rax
- Multitom
- Mulitom
- Rax
- 3D
- Real 3D
- Preforming Real 3D
- Performing Real 3D
- Performing 3D[